A fully integrated system combining patented LED curing technology with approved light-curing pipe liners. It is used for the trenchless rehabilitation of wastewater pipes.
A pipe liner impregnated with light-curing resin is inserted into the existing pipe and pressed against the pipe wall using air pressure. An LED head is then inserted into the liner. The blue light cures the liner to form a new, structurally sound pipe within the existing pipe.
LEDs are most efficient in the visible light spectrum. Bluelight therefore uses visible blue light at around 450 nm (444–457 nm), rather than the UV spectrum, which is invisible to the human eye. The resin systems used by Bluelight contain special proprietary initiators so that the resin can absorb the energy from the light source as effectively as possible.
At 0.30 to 1.65 m per minute, equivalent to 18 to 99 m per hour. The exact rate depends on the liner type, diameter, wall thickness and LED head used.
The PAA F-Liner covers DN70 to DN400. The PAA GF-Liner covers DN150 to DN600, as well as egg-shaped profiles from DN200/300 to DN400/600.
Up to 120 metres in one continuous section. Longer sections are possible in exceptional cases, but curing must then be carried out from both ends.
Yes. The PAA F-Liner is flexible and can negotiate bends; depending on the product, it can accommodate changes of two or three nominal diameter sizes. The PAA GF-Liner cannot negotiate bends and has very limited flexibility, so it can only accommodate angular deviations of up to 15 degrees. Changes in nominal diameter are not possible with the PAA GF-Liner.
Yes, open-ended installations are possible with the PAA F-Liner. A special light-transmitting inner calibration hose is used for this purpose.
The F-Liner is based on a flexible synthetic-fibre carrier with a PU coating. It is installed by inversion. It is particularly suitable for lateral connections and underground drainage pipes, as well as smaller main sewers with alignment deviations, changes in nominal diameter or bends. The GF-Liner is based on glass-fibre carriers. It is always pulled into place and is designed for straight runs from manhole to manhole.
PAA F-Liners are impregnated exclusively with styrene-free vinyl ester resin (AP450). PAA GF-Liners are normally impregnated with styrene-containing polyester resin (PB450). Where specific requirements apply, PAA GF-Liners can be impregnated with styrene-free vinyl ester resin (AP450) on a case-by-case basis.
Users can purchase pre-impregnated PAA F-Liners, or buy dry F-Liners together with the corresponding resin and impregnate them themselves. PAA GF-Liners are only available pre-impregnated.
The process technology is approved by DIBt (Germany), WRC (United Kingdom) and CSTB (France). The approvals are available here on the website: Materials page.
Pipe liners that have been tested for suitability, approved, and properly installed and cured by trained users can achieve service lives of more than 50 years in practice.
When styrene-free resins are used, the process is completely odourless and produces low emissions. Styrene-containing resin may produce slight odours. Compared with heat-curing systems, Bluelight technology reduces on-site CO2 emissions by 90 to 99%. Silicone inner calibration hoses can be reused.
Construction time is short, rehabilitated sections are quickly returned to service, chemical odours are absent or minimal, and no excavation is required. The pipe is then watertight and structurally sound again.
The system is fully software-controlled and automatically records all relevant parameters. The liner can be inspected by camera before curing. In addition, the group’s own laboratories test raw materials and samples of liners cured on site.
No. Bluelight is a trading company and does not enter into contracts to carry out rehabilitation work. Rehabilitation is performed by Bluelight users. Lists of users can be found here: Users.
Yes. Bluelight rents out a demonstration unit together with a qualified application technician for a demonstration project.
Yes. The purchase includes one to two weeks of personal on-site training during each new user’s first projects. Regular user training, remote maintenance and service workshops in Germany and Denmark are also available.
A laser measuring device that determines a sewer’s diameter, circumference and shape from above through the manhole, without anyone having to enter it. It measures in the DN100–DN1000 range (up to DN1500 for concrete), with a typical deviation of approximately ±2%, and can be operated via an app without training.